Skip to article frontmatterSkip to article content
Site not loading correctly?

This may be due to an incorrect BASE_URL configuration. See the MyST Documentation for reference.

In Chapter 15 "Nuclear Chemistry", Section 15.2 "Half-Life", we used mass to indicate the amount of radioactive substance present. Its activity is the number of nuclear decays per unit time. Radiation dose describes energy deposited in matter and, with appropriate weighting, its effects on tissue. Activity and dose measure different quantities.

Perhaps the direct way of reporting radioactivity is the number of radioactive decays per second. One decay per second is called one becquerel (Bq) (A unit of radioactivity equal to 1 decay per second.). Even in a small mass of radioactive material, however, there are thousands upon thousands of decays or disintegrations per second. The unit curie (Ci) (A unit of radioactivity equal to 3.7×10103.7\times{}{10}^{10} decays/s.), now defined as 3.7 × 1010 decays/s, was originally defined as the number of decays per second in 1 g of radium. Many radioactive samples have activities that are on the order of microcuries (µCi) or more. Both the becquerel and the curie can be used in place of grams to describe quantities of radioactive material. As an example, the amount of americium in an average smoke detector has an activity of 0.9 µCi. (The curie is named after Polish scientist Marie Curie, who performed some of the initial investigations into radioactive phenomena in the early 1900s; the becquerel is named after Henri Becquerel, who discovered radioactivity in 1896.)

Radiation can transfer energy to tissue through moving particles and through the absorption of electromagnetic radiation such as gamma rays. The energy deposited per unit mass is called absorbed dose. Its SI unit is the gray (Gy) (An absorbed dose of 1 joule per kilogram.). The older unit rad (An absorbed dose of 0.01 joule per kilogram.) is still encountered, especially in US sources:

1 Gy=1 J/kg=100 rad1\ \mathrm{Gy} = 1\ \mathrm{J/kg} = 100\ \mathrm{rad}

The gray is the SI unit used in scientific reporting. Absorbing 1 rad in a 70 kg body deposits only 0.7 J, but ionizing radiation can damage molecules and cells even when its overall heating effect is very small.

Radiation types differ in their biological effects. For a tissue exposed to one type of radiation, the equivalent dose is its mean absorbed dose multiplied by a radiation weighting factor:

equivalent dose (Sv)=absorbed dose (Gy)×radiation weighting factor\text{equivalent dose (Sv)} = \text{absorbed dose (Gy)} \times \text{radiation weighting factor}

The sievert (Sv) (The SI unit of equivalent dose and effective dose.) is related to the older rem (A unit of equivalent dose or effective dose equal to 0.01 sievert.) by 1 Sv = 100 rem. The weighting factor is 1 for photons and beta particles and 20 for alpha particles. Effective dose additionally weights the equivalent doses to different organs and tissues to account for differences in their sensitivity. These quantities are explained in the FDA’s radiation units guide and OSHA’s radiation background reference.

Annual effective dose depends on location, housing, medical procedures, and other circumstances. Table 15.3 "Average Annual Radiation Exposure (Approximate)" gives a dated US population benchmark summarized by the Nuclear Regulatory Commission. It represents 2006 exposure data reported by NCRP in 2009. Roughly half came from natural background and half from human activities, mainly medicine. Natural background includes radon, cosmic radiation, terrestrial radiation, and radioactive isotopes in the body, including potassium-40 and carbon-14.

Table 1:Average Annual Radiation Exposure (Approximate)

Source (US population, 2006 benchmark)Effective dose (mSv/year)Effective dose (mrem/year)
natural background3.1310
human activities, mainly medical procedures3.1310
Total6.2620

Source: NRC, Doses in Our Daily Lives, summarizing NCRP Report No. 160 (2009). Values are rounded population averages, not an individual’s dose or a universal annual value.

Exposure patterns change. An updated study using 2016 US medical exposure data estimated the medical contribution at about 2.3 mSv per person per year, compared with about 2.9 mSv in 2006 using comparable methods. This medical-only estimate does not replace the total in Table 15.3. Also, “natural” does not mean “unavoidable”: testing homes for radon and reducing elevated levels can lower exposure. See the EPA’s radon guide.

Health effects depend on absorbed dose, radiation type, the tissues exposed, and how quickly the dose is delivered. Table 15.4 "Effects of Short-Term Exposure to Radioactivity and Radiation" summarizes approximate acute effects of penetrating radiation delivered to most of the body in a short time. These dose ranges overlap and do not predict an individual outcome. Effective dose in sieverts is used for radiation protection comparisons; absorbed dose in grays is used here to describe acute injury.

Table 2:Effects of Short-Term Exposure to Radioactivity and Radiation

Absorbed dose (Gy)Possible acute effects
about 0.3 and abovemild symptoms of radiation sickness may occur
about 0.7–10bone marrow injury; risk of infection and bleeding increases as dose rises
about 6 and abovegastrointestinal symptoms may occur
above about 10severe gastrointestinal syndrome; survival is extremely unlikely

Source: CDC, Acute Radiation Syndrome: Information for Clinicians. Outcomes also depend on treatment, dose distribution, and dose rate. This table describes acute injury; it does not establish a threshold below which long-term cancer risk is absent.

A personal dosimeter measures radiation received by its wearer. Film badges provide a historical example: radiation darkens the film, and comparison with calibrated exposures allows dose to be estimated. Thermoluminescent, optically stimulated luminescent, and electronic dosimeters are also used. A dose estimate requires calibration appropriate to the radiation and measurement conditions.

Another means of detecting radioactivity is an electrical device called a Geiger counter (An electrical device that detects radioactivity.) (Figure 15.2 "Detecting Radioactivity"). It contains a gas-filled chamber with a thin membrane on one end that allows radiation emitted from radioactive nuclei to enter the chamber and knock electrons off atoms of gas (usually argon). The presence of electrons and positively charged ions causes a small current, which is detected by the Geiger counter and converted to a signal on a meter or, commonly, an audio circuit to produce an audible “click.”

A portable Geiger counter with a meter and a connected detector probe.

Figure 15.2:Detecting Radioactivity. A Geiger counter and its connected probe detect ionizing radiation. Radiation entering the detector produces electrical pulses that can be displayed or heard as clicks.

Credits: Geiger counter 2 — TimVickers, Public domain. Images resized for the web.

Exercises